StartNot sure where to start? Pick your standard in 1 minute — free, no registration. Members: sign in with email on the right.
Academy/ISO/IEC 17025

ISO/IEC 17025 Academy

2017 current edition · flagship

Eight accreditation bodies, eight dense rule sets. This academy compresses them into one short path: the 4-tier document skeleton, 119 compliance checkpoints, the document template library (44 forms free forever), and body-by-body breakdowns of what each adds beyond the ISO/IEC 17025 text.

8
frameworks decoded
119
checklist items
81
document templates
44
forms & records — free forever
Run the reality diagnosis

The eight accreditation bodies, decoded

What does each body add beyond ISO/IEC 17025, and which documents does it mandate? Start with the cross-body cheat sheet, then open the card of your target body for the full deep-read — complete Chinese and English editions, free to read, no signup.

Most wantedNEWFree

Eight accreditation bodies at a glance

A side-by-side read of what Global ACI / CNAS / A2LA / UKAS / NVLAP / NATA / SINGLAS / NABL each add beyond ISO/IEC 17025 — which clauses are unique, which documents are mandatory. One sheet instead of eight websites.

Read the full guide →
Global MRANEWFree

Global ACI · Specific requirements beyond ISO/IEC 17025

Global ACI (formerly ILAC, whose role it assumed on 1 Jan 2026) is not an accreditation body but the global mutual-recognition framework (MRA). Before claiming MRA on reports, master P8 (mark usage), R7 (combined marks) and P9 (PT policy) — legacy ILAC document numbering still applies.

ChinaNEWFree

CNAS · Specific requirements beyond ISO/IEC 17025

CNAS layers Chinese-language controlled documents on 17025: CL01/CL01-G application requirements, PT frequency, intermediate checks and auditor competence — mapped clause by clause for CNAS assessment.

USANEWFree

A2LA · Specific requirements beyond ISO/IEC 17025

A2LA adds traceability policy, PT policy, record-retention periods and witness-assessment rules — the clauses most likely to raise nonconformities when entering the North American market.

UKNEWFree

UKAS · Specific requirements beyond ISO/IEC 17025

UKAS sharpens 17025 through its GEN/LAB/TPS publications: decision rules in LAB 48, report wording in TPS 53, uncertainty per M3003 — UK-market reports usually trip on exactly these details.

USANEWFree

NVLAP · Specific requirements beyond ISO/IEC 17025

NVLAP (under NIST) operationalizes 17025 via the Handbook 150 series: dedicated clauses on PT, metrological traceability and certificate/logo use — critical for calibration labs.

AustraliaNEWFree

NATA · Specific requirements beyond ISO/IEC 17025

NATA layers its SAD Standard Application Document and GAC/GAG general criteria and guidance on top of 17025: equipment assurance, traceability, PT and equipment checks each carry dedicated clauses — find your field's SAC (Specific Accreditation Criteria) first and NATA assessment gets far easier.

SingaporeNEWFree

SINGLAS · Specific requirements beyond ISO/IEC 17025

SINGLAS follows the Global ACI framework with local additions: mark usage, subcontracting and conformity-statement wording — walk through them before applying in Singapore.

IndiaNEWFree

NABL · Specific requirements beyond ISO/IEC 17025

For labs targeting the Indian market: what NABL adds on top of ISO/IEC 17025 — infrastructure, personnel competence, internal-audit cadence and on-site assessment points, with real nonconformity examples.

Per-body accreditation criteria list
Global ACI MRAGlobal ACI
Key document list
  • Global ACI TECH-1-009Global ACI Policy for Uncertainty in Calibration(原 ILAC P14)
ChinaCNAS
Key document list
  • CNAS-CL01:2018Accreditation Criteria for the Competence of Testing and Calibration Laboratories
  • CNAS-CL01-G001:2024Application Requirements for CNAS-CL01
  • CNAS-GL011Guidance on Internal Audits for Laboratories and Inspection Bodies
  • CNAS-GL012Guidance on Management Reviews for Laboratories and Inspection Bodies
  • CNAS-GL042Guidance on Intermediate Checks of Measuring Equipment
USAA2LA
Key document list
  • A2LA R205General Requirements for Accreditation
  • A2LA R101General Requirements: Accreditation of CABs
  • A2LA R102Conditions for Accreditation
  • A2LA R103General Requirements: Proficiency Testing
  • A2LA R105Reference to A2LA Accredited Status
USANVLAP
Key document list
  • NIST HB 150-2020upd1NVLAP Procedures and General Requirements
  • NIST HB 150-2-2024NVLAP Calibration Laboratories
  • NIST HB 150-1-2021NVLAP Energy Efficient Lighting
  • NIST HB 150-3-2025Asbestos Fiber Analysis
  • NIST PG 17-2024Expiration as Voluntary Termination
UKUKAS
Key document list
  • UKAS GEN 1General Requirements for Accreditation
  • UKAS GEN 4Flexible Scope
  • UKAS GEN 6Use of Accreditation Symbols & Marks
  • OPSSNational Accreditation Mark Conditions
  • UKAS LAB 5Calibration
AustraliaNATA
Key document list
  • NATA SAD 2017Supplementary Accreditation Document
  • NATA GAC TraceabilityMetrological Traceability Policy
  • NATA GAC PTProficiency Testing Policy
  • NATA GAC Equipment AssuranceEquipment Assurance & In-house Calibration
  • NATA GAG BalancesUser Checks of Balances
SingaporeSINGLAS
Key document list
  • SINGLAS-001General Criteria for SAC-SINGLAS Accreditation
  • SINGLAS-006Metrological Traceability
  • SAC-02Use of SAC Mark
  • PROF-001Proficiency Testing
  • TechGuide-1Estimation of Uncertainty (Testing)
IndiaNABL
Key document list
  • NABL 100BGeneral Criteria for Testing Labs
  • NABL 129Calibration Specific Criteria
  • NABL 130Field / Mobile Laboratory
  • NABL 131Terms & Conditions
  • NABL 133Use of NABL Symbol
Compared all eight? Now turn them into your lab's own documents.
Subscribe to get the full 8-body cheat sheet · new breakdowns land in your inbox first · one practical letter a week

Lab Journal

Only what checks out against primary sources for this standard: edition updates, accreditation-governance changes, and rumor debunking. Every piece carries a fact-check appendix.

2026-10-26IAF and ILAC are gone: Global ACI explained for laboratoriesSince 1 January 2026, IAF and ILAC have been replaced by Global ACI — one organisation, one MRA. What actually changed, what didn't, how long the ILAC MRA mark stays valid, and what labs should do now.Read the piece →2026-10-10ISO 17025:2025 doesn't exist — here's the truthThere is no ISO/IEC 17025:2025. The current edition is 17025:2017 — how to verify in 30 seconds, where the rumor comes from, and what labs should actually do.Read the piece →

Browse the full journal →

Other academies

ISO 9001 AcademyISO 14001 AcademyISO 45001 AcademyIATF 16949 Academy

Resources on this page are compiled from publicly published accreditation-body documents (references, titles and paraphrases only — no verbatim text), for internal preparation and study only; they do not constitute accreditation-body decisions or legal advice. ISO/IEC 17025 is a trademark of ISO/IEC.